Your query posted successfully. We will get back to you soon.
,

Honeywell AWM43300V Sensor

Availability:

2 in stock (can be backordered)


Compensated or uncompensated. ±25.0 SCCM, 1.0 SLPM, 6.0 SLPM. Analog output

8,071.20

incl. GST

Availability: 2 in stock (can be backordered)

2 in stock (can be backordered)


Special price on bulk order

Secure Payment

Fast & Quick Delivery

Technical Support

Honeywell AWM43300V Sensor Introduction

Honeywell AWM43300V Sensor Series Airflow Sensors are based on proven microbridge technology and include both unamplified sensor-only devices and amplified signal conditioned devices. The microbridge mass airflow sensor operates on the theory of heat transfer. Mass airflow is directed across the surface of the sensing elements. Output voltage varies in proportion to the mass air or other gas flow through the inlet and outlet ports of the package. AWM43300V sensor has a unique silicon chip based on advanced microstructure technology. It consists of a thin film, thermally-isolated bridge structure containing heater, and temperature sensing elements. The bridge structure provides a sensitive and fast response to the flow of air or other gas over the chip.

Dual sensing elements positioned on both sides of a central heating element indicate flow direction as well as flow rate. The specially-designed housing precisely directs and controls the airflow across the microstructure sensing element. Mechanical design of the package allows it to be easily mounted to printed circuit boards. Laser-trimmed, thick film and thin film resistors provide consistent interchangeability from one device to the next. The microbridge mass airflow sensor uses temperature sensitive resistors deposited within a thin film of silicon nitride. They are suspended in the form of two bridges over an etched cavity in the silicon.

Honeywell AWM43300V Sensor Feature

  • Precision silicon micromachining.
  • Sensitivity to low flows (0.1 SCCM to 6 SLPM).
  • Adaptable for use with higher flows.
  • Low power consumption allows for use in portable devices and battery powered applications.
  • Analog output.
  • Standard 2,54 mm [0.10 in] mounting centers.
  • Laser-trimmed interchangeability.
  • Accurate sensing of low pressure.

APPLICATIONS

  • Medical
    • Respirators and ventilators.
    • Oxygen concentrators and conservers.
    • Anesthesia machines.
  • Industrial
    • HVAC damper control.
    • Gas analyzers.
    • Low vacuum control.
    • Process control.
    • Leak detection equipment.
    • Vent hoods.
    • Gas metering.
    • Chromatography.
SKU: AWM43300V Sensor Categories: ,
Characteristic AWM43300V
Flow range (full scale) +1000 SCCM
Calibration gas Nitrogen
Recommended excitation voltage 10.000 ±0.010 Vdc
Power supply:
minimum
maximum
8.000 Vdc
15.000 Vdc
Power consumption 60 mW max
Output at laser trim point 5 Vdc ±0.15 Vdc at
1000 SCCM
Null output 1.0 mVdc ±0.05 mVdc
Null output shift (-25°C to 85°C) ±0.025 Vdc max.
Output voltage shift:
25°C to -25°C
25°C to 85°C
-5.0% reading max.
+6.0% reading max
Repeatability and hysteresis ±0.5% reading max
Pressure drop at full scale 1.02 inH20 typ.
Response time 1.0 ms nom
Overpressure 10.3 bar [150 psi]
Maximum flow pulse to
prevent damage
5 SLPM/s
Output load:
NPN (sinking)
PNP (sourcing)
10 mA
20 mA
Operating temperature range -25°C to 85°C
[-13°F to 185°F]
Storage temperature range -40°C to 90°C
[-40°F to 194°F]
Ratiometricity error ±0.3% reading nom.
Shock (5 drops, 6 axes) 100 g peak

Download

Datasheet

Leave a Reply

Your email address will not be published. Required fields are marked *

Bulk Enquiry

Name

Phone*

Email*

Comment