Your query posted successfully. We will get back to you soon.
,

Current Sensor Module WCM2702

Availability:

Backorder (Delivery in 2-4 Weeks)


AC / DC Sensing Current Module with Digital Data output

767.00

incl. GST

Availability: Backorder (Delivery in 2-4 Weeks)


Special price on bulk order

Secure Payment

Fast & Quick Delivery

Technical Support

Current Sensor Module WCM2702 Introduction

Current Sensor Module WCM2702 provides economical and precise solution for both AC and DC current sensing in industrial, commercial and communications systems. The WCM2702 consists of a current sensor, temperature sensor, a very high accuracy A/D converter and digital signal output of current. The WCM2702 includes a current path with 98 mΩ typical internal conductor resistance. This extremely low resistance can effectively reduce power loss, operating temperature and increase the reliability greatly, user’s
MCU can get the real data from DATA pin.

The WCM2702 provides temperature calibration of the internal current sensor and accurately measures the current of AC 50 / 60Hz and DC at temperature from -20ËšC~70ËšC. The WCM2702 also offers solutions for true RMS current measurement of various loads.

Features

  • Continuous output and Modbus-RTU version.
  • Operating voltage DC5.0V.
  • 98 mΩ internal conductor resistance.
  • Sensing current range :
    AC : 0~1.2A (50Hz, 60Hz)
    DC : 0~±1.7A
  • High accuracy :
    AC : (0~0.4A) ± 4mA
    (0.4~1.2A) ± 1%
    DC : ±(0~0.4A) ± 4mA
    ±(0.4~1.7A) ± 1%
  • High resolution :
    AC / DC : 1.2mA
  • UART, Baud Rate : 9600 bps, Parity bit : None, Data bit : 8,Stop bit : 1
  • Temperature calibration.
  • Isolation Voltage 1KV.
SKU: Module WCM2702 Categories: ,
Symbol Parameters Test Conditions Min. Typ. Max. Unit
VDD Operation Voltage 4.9 5 5.1 V
IDD Operation Current 6 8 mA
Rprimary Conductor Resistance IP= 2A 98 mΩ
TOP Operating Temperature -20 70 0C

-AC50C

Symbol Parameters Test Conditions Min. Typ. Max. Unit
IOP AC Current Range 0 1.2 A
ETOT AC Current Total Output Error IOP=0~0.4A,TOP=25˚C ±4 mA
IOP=0.4~1.2A,TOP=25˚C ±1 %
IOP=0~1.2A,
TOP=-20ËšC to 70ËšC
±5 %

-DC50C

Symbol Parameters Test Conditions Min. Typ. Max. Unit
IOP DC Current Range 0 ±1.7 A
ETOT DC Current Total Output Error IOP=±(0~0.4A),TOP=25˚C ±4 mA
IOP=±(0.4~1.7A),TOP=25˚C ±1 %
IOP=0~±1.7A,
TOP=-20ËšC to 70ËšCTOP=-20ËšC to 70ËšC
±5 %

Download